Detailed Description
The following address map holds (all accesses are
read/write):
address 0 : r/w : Slink Control register
- bit 0 : if '1' the
status if the Slink will be ignored. That means operation
continues a s if there was a Slink connected always ready
to receive data. The l_down and l_ff states are ignored.
- bit 1 : if '1' an empty event is sent in case of
detection of some error.
- bit 2 : read only: is the lff bit of the SLINK
- bit 3 : read only: is the ldown bit of the SLINK
address 1 : r/w : ControlRegister.
- bits 6..3 : 4 bits maximal muon count MINUS ONE sent to
Lvl2.
- bit 2 : if '1' offset for BCIDSelector is added if '0'
offset is subtracted in order to calculate the BCID for
which to transfer data to Lvl2.
- bits 1..0 : 2-bit offset for BCIDSelector to calculate
the BCID which is sent to Lvl2. The offset is added or
subtracted (according to the state of bit 2) from the
Lvl1A BCID.
address 2 : 8 bit trigger type to be suppressed.
- For the selected TriggerType an empty event is sent to
Lvl2. Remember to set this to a trigger type which is not
used if you do NOT want to make use of this feature,
since there is no switch to turn the feature off.
See also: Lvl2Processor